20010906 report
New track model - updated inclinometer scales used
Datasets HST mean leg temperatures Humidity
start start middle end %
( 20010815 cw 20:20 7.2 7.0 6.9 70 )
20010906 cw 02:30 2.8 3.2 3.2 100
The difference between the latest CW model (processed in the 'old' way
using inclinometer scales of 20.0mV/arcsec) and the previous one is shown
below :
- The formal differences in
(F1,F2,F3)
are described by the rms scatters of
( 0.58" , 0.46" , 0.52" )
cf
(0.65", 0.45", 0.59")
previously;
- so the track profile remains stable.
- The data were also reduced with the scales changed to
20.8mV/arcsec, as a result of experiments during the night on the
Y-axes of the 'TMU' inclinometer and the 'Spare' inclinometer.
Individual results were 20.9 and 20.7, respectively.
- Installation of the new track model occurred at
09:30 HST 06 September 2001.
- The symmetry remains elevated, but
stable
- see the plot.
- The strain gauge data are also
updated, and appear normal.
Iain Coulson
Latest Update : 06 Sep 2001
|