20030329 report
CW & CCW Inclinometry, OK
Inclinometry was done as follows :
Datasets El Dirn HST mean leg temperatures Humidity
start start middle end %
( 20030314 90 cw 10:25 3.8 5.0 6.0 16 )
20030328 90 cw 22:50 6 5 4 85
20030329 90 ccw 01:20 4 3 2 85
All data channels (particularly those from the 'fixed' TMU inclinometer)
were OK.
The resulting CW model is compared with previous model -- the one
taken on 14 Mar -- and the CW & CCW models
are also compared, below:
The new CW data are mildly different from those of the
01st, showing distinct segment-sized lumps indicative
of a reorientation of one of the wheels. Nonetheless, they
are used to create a new track model.
The CW-CCW difference is essentially unchanged from the last time
such a pair of measures was made :
22 Oct 2002.
-
The differences in
(F1,F2,F3)
are described by the rms scatters of
(0.36", 0.39", 0.48") (CW-CW) and (1.26", 0.22", 0.48") (CW-CCW)
c.f.
(0.32", 0.55", 0.30") (CW-CW)
previously.
-
Updates have been made to the plots of
symmetry
and
strain gauge data.
All looks OK.
-
The CW model was installed at 14:00 HST on 01 Apr 2003.
20030412
The above (CW-CCW) data was averaged with the 3 previous such measures
taken during 2002 & 2003 to generate a
mean (CW-CCW) profile,
which
will find use in the generation of
hybrid track model,
the first of which was installed on
20030412.
Iain Coulson