CW & CCW Inclinometry, OK
Inclinometry was done as follows :
Datasets El Dirn HST mean leg temperatures Humidity
start start middle end %
( 20041230 90 cw 23:59 3.3 3.4 3.5 30 )
20050106 90 cw 22:00 -1.5 -1.6 -1.6 60
20050107 90 ccw 02:00 -1.6 -1.7 -1.6 45
All data channels look OK; the difference between the CW model resulting
from the new CW data and the current one (of 30
Dec) is shown below:
Click on image for better view
-
The differences in
(F1,F2,F3)
are described by rms scatters of
(0.38", 0.89", 0.75")
c.f.
(0.28", 0.13", 0.28")
previously.
-
The new CW model was merged with the
(CW-CCW) template
to create a
new hybrid track model,
which was installed at HST 10:00 on 07 January 2005.
-
The
symmetry
(defined here)
remains at an elevated level.
As last time, however, the explanation cannot
be underloading of the front wheels,
since the wheel loads -
as judged from strain gauge No.2 only - are OK.
(Strain gauge No.1 remains inoperative).
The CCW data will be examined in the
next report
|