20070408 report
CW/CCW inclinometry
Inclinometry was performed as follows:
Datasets El Dirn HST mean leg temperatures Humidity
start start middle end %
( 20070318 89 cw ~07:00 - - - -
20070318 89 ccw ~09:30 - - - - )
20070408 89 cw ~08:00 6.7 7.5 8.2 16
20070408 89 ccw ~10:15 8.2 8.8 9.5 16
Data is recorded from the 3 active inclinometers only:
there is no strain gauge data, for instance.
-
The differences between the (CW) model derived from these new data
and the previous model of 18 Mar
are shown below :
Click for better image
-
- The noise in Ch2 is lower (better) than in recent times.
- The rms scatter in the differences in (F1,F2,F3) are
(0.48", 0.41", 0.77")
cf. (0.32", 0.20", 0.86")
previously.
-
The difference between the CW and CCW models is shown below:
. . . and is of the smaller amplitude type as seen, eg,
last time.
The CW-CCW data were used to generate
a hybrid track model,
installed at HST 13:50 on 09 Apr 2007.
|