20080328 report
CW inclinometry OK
Inclinometry was performed as follows:
Datasets El Dirn HST mean leg temperatures Humidity
start start middle end %
( 20080209 89 cw ~21:30 3.6 3.4 3.2 25 )
20080328 89 cw ~06:30 1.9 2.0 2.4 40
20080331 89 ccw ~07:00 1.1 1.4 2.0 10
Data is recorded from the 3 active inclinometers and one of the two
strain gauge channels. The LT trace is again low, but not abnormally so
as previously; nonetheless, the RT
data is used to correct LX & LY.
-
The differences between the (CW) model derived from these new data
and the previous model of 09 Feb
are shown below:
Click for better image
-
The features of amplitude 1"-2" and wavelength of about 9degrees
appeared previously and may be present only
in the previous data.
The rms scatter in the differences in (F1,F2,F3) are
(0.50", 0.42", 0.75")
cf (0.32", 0.41", 0.48")
previously.
-
The CW-CCW data
of 20071223
were used to generate a
hybrid track model,
installed at ~HST 13:37 on 28 Mar 2008.
The CW-CCW data
of 20080331
are of the usual 'small amplitude' variety, and were also used to update the
hybrid track model.
This new model was installed at ~HST 12:20 on 31 Mar 2008.
The symmetry and the
strain gauge data are OK.
|