20090106 report

CW/CCW inclinometry updated

06 Jan 2009


Inclinometry was acquired as follows:

   
   Datasets     El   Dirn      HST       mean leg temperatures     Humidity
                              start      start   middle   end         %
   (20081211    89     cw    ~07:00       5.0     5.0     5.4         10
    20081211    89    ccw    ~09:30       5.4     6.2     7.0         25)
    20090103    89     cw    ~04:00       1.5     1.5     1.5         95
    20090103    89    ccw    ~06:45       1.5     1.6     1.8         98


The new data are recorded from the 3 active inclinometers and one of the two strain gauge channels. The LT trace which has had problems previously appears to running normally again.


  • The differences between the (CW) model derived from the new data and the previous model of 16 Dec are shown below:

    Click for larger image

  • The resulting rms scatters in the differences in (F1,F2,F3) are (0.45", 0.67", 0.25") cf. (0.32", 0.26", 0.18") last time.

  • The CW-CCW profile is normal, and is used to generate a hybrid track model which was installed at ~HST 15:00 on 06 January 2009.

  • The symmetry and the strain gauge data for the one remaining channel looks as expected.


Contact: Holly Thomas. Updated: Tue Feb 3 17:20:28 HST 2009