20090203 report
CW/CCW inclinometry updated
03 Feb 2009
Inclinometry was acquired as follows:
Datasets El Dirn HST mean leg temperatures Humidity
start start middle end %
(20090103 89 cw ~04:00 1.5 1.5 1.5 95
20090103 89 ccw ~06:45 1.5 1.6 1.8 98)
20090131 89 cw ~06:30 3.3 3.6 3.9 3
20090131 89 ccw ~09:15 3.9 5.0 5.8 8
The new data are recorded from the 3 active inclinometers and one of the
two strain gauge channels.
The LT trace which has had problems previously continues to run normally.
-
The differences between the (CW) model derived from the new data
and the previous model of 6th Jan
are shown below:
Click for larger image
-
The resulting rms scatters in the differences in (F1,F2,F3) are
(0.54", 0.77", 0.72")
cf.
(0.45", 0.67", 0.25")
last time.
-
The
CW-CCW profile
is normal, and is used to generate a
hybrid track model
which was installed at ~HST 16:00 on 03 February 2009.
-
The symmetry and
the strain gauge data
for the one remaining channel looks
as expected.
|