20090727 report
CW/CCW inclinometry updated
27 July 2009
This inclinometry run was carried out on 26th July.
Datasets El Dirn HST mean leg temperatures Humidity
start start middle end %
(20090718 89 cw 08:15 5.5 6.0 6.7 55
20090718 89 ccw 11:30 6.7 7.7 9.0 45)
20090726 89 cw 07:00 6.5 7.0 7.6 20
20090726 89 ccw 10:15 7.6 8.9 9.8 30
The new data are recorded from the 3 active inclinometers and one of the
two strain gauge channels. The LT trace, which showed strange behaviour during the previous inclinometry run now shows no problems.
-
The differences between the (CW) model derived from this run and the previous run on 18th July are shown below.
Click for larger image
-
The resulting rms scatters in the differences in (F1,F2,F3) are (0.38", 0.29", 0.35") compared to (0.35", 0.48", 0.25") last time.
-
The
CW-CCW profile is normal, and is used to generate a hybrid track model
which was installed on the 20th July at 11:00.
- The strain gauge analysis suggest the loasing on the wheels continues to hold steady. (see strain gauge data).
|