20090817 report
CW/CCW inclinometry updated
17 August 2009
This inclinometry run was carried out on 15th August.
Datasets El Dirn HST mean leg temperatures Humidity
start start middle end %
(20090801 89 cw 06:45 6.2 6.6 7.1 30
20090801 89 ccw 09:30 7.1 7.8 8.6 55)
20090815 89 cw 07:15 7.4 8.0 8.7 45
20090815 89 ccw 10:00 8.7 9.7 10.3 60
The new data are recorded from the 3 active inclinometers and one of the
two strain gauge channels. The LT trace, which showed strange behaviour during the previous inclinometry run continues to show no problems.
-
The differences between the (CW) model derived from this run and the previous run on 1st August are shown below.
Click for larger image
-
The resulting rms scatters in the differences in (F1,F2,F3) are (0.34", 0.38", 0.30") compared to (0.31", 0.25", 0.36") last time.
-
The
CW-CCW profile is normal, and is used to generate a hybrid track model
which was installed on the 16th August at 11:30.
- The strain gauge analysis suggest the loading on the wheels continues to hold steady (see strain gauge data).
|