990108 report
New Conventional Inclinometry - including doors open -vs- doors closed
SUMMARY
During poor weather, conventional nighttime inclinometry was obtained, and
a new track model installed for the first time since 981117.
CW runs with the dome doors closed are little different
from data taken with the doors open.
Datasets HST start mean leg temperatures Humidity
start middle end %
inc990107 (open) 21:15 4.5 4.1 3.7 60
inc990108 (closed) 00:20 3.4 3.1 3.1 65
The differences between the models derived from these new data and between
the models of 990107 and 981117 are shown below :
The data show a couple of electronic spikes (located within the 990107
data) which were removed before the creation of the track model.
There is otherwise good agreement between data taken with the doors
open and closed : rms scatters in the (F1,F2,F3) differences of
(0.25",0.23",0.52"). Between the models of 990107 and 981117 the
differences are somewhat worse at (1.0",0.4",0.6"), but not bad in the
context of recent problems. A small amplitude ripple
is present in the latter plot that is suggestive of a change
in the ripple characteristics of one of
the wheels. This is analysed further below.
L-R symmetry
The 990107 data are used to update the symmetry measures, reverting to
using RY as a reference :
| date |
TY -vs- RY |
LY -vs- RY |
LY -vs- TY |
SY -vs- TY |
| 981107 |
0.69 |
2.84 |
2.85 |
  |
| 981109 |
0.69 |
3.08 |
3.03 |
  |
| 981110 |
0.67 |
1.98 |
1.92 |
  |
| 981111 |
0.65 |
2.47 |
2.46 |
  |
| 981112 |
0.72 |
2.34 |
2.18 |
  |
| 981114 |
0.78 |
1.22 |
1.05 |
  |
| 981115 |
  |
  |
2.13 |
1.52 |
| 981117 |
0.68 |
1.34 |
1.29 |
  |
| 981120 |
  |
  |
2.05 |
1.42 |
| 981121 |
  |
  |
1.95 |
1.36 |
| 981122 |
  |
  |
1.82 |
1.25 |
| 981126 |
  |
  |
1.97 |
1.32 |
| 981128 |
  |
  |
1.86 |
1.27 |
| 981207 |
  |
  |
2.09 |
1.52 |
| 981210 |
  |
  |
2.24 |
1.70 |
| 981212 |
  |
  |
1.98 |
1.27 |
| 981213 |
  |
  |
2.02 |
1.41 |
| 990104 |
  |
  |
1.67 |
1.17 |
| 990107 |
0.68 |
1.52 |
1.50 |
  |
'Good'
symmetry persists.
The
plot of these
symmetry
data is updated.
The data are also used to update the
plot showing the amplitude and phase of the ripples in the right and
left A-frame inclinometry data. A substantial reduction in the ripple
from the right side is evident, as was suggested by the inspection above.
Conclusions
-
A new track model was installed on 990108. It appears little different
from that in use these past 7+ weeks.
-
The state of the dome doors seems unimportant to the inclinometry
measures of the track.
Iain Coulson
08 Jan 1999
|