____________________
|
|
|
|
JCMT Pointing Reports - 2007
JCMT Pointing Reports - 2007
-
Jan 03
- HARP array-centred pointing
-
Jan 11
- HARP array-centred pointing - analysis for optimal (xo yo x' y')
-
Jan 13
- RxA pointing run
-
Jan 31
- CW inclinometry - substantial changes since November
-
Feb 06
- RxA pointing run - performance unimproved
-
Feb 10
- CW/CCW inclinometry
-
Feb 21
- RxA pointing run : new model installed 20070226, should yield (dS,dZ) = (2.0",2.2")
-
Feb 26
- CW inclinometry OK
-
Feb 28
- RxA pointing run : new model confirmed
-
Mar 01
- Analysis of fake, perfect, pointing data
-
Mar 04
- CW/CCW inclinometry OK
-
Mar 06
- HARP pointing - optimal (xo yo x' y' x2 y2) = (0 0 0 0 0 0) ?
-
Mar 14
- Further Analysis of fake, perfect, pointing data : 7 model
parameters set to ( 0 0 0 0 0 0 0 )
-
Mar 18
- CW/CCW inclinometry OK
-
Apr 08
- CW/CCW inclinometry OK
-
Apr 09
- Pointing performance update
-
Apr 10
- Focus performance update
-
Apr 12
- RxA pointing run : model update
-
Apr 17
- HARP pointing
-
Apr 26
- HARP pointing update
-
May 02
- HARP FIVEPOINT-ing
-
May 06
- HARP pointing run - a solution for 4 k-mirror terms ?
-
May 11
- HARP pointing update
-
May 14
- HARP pointing - receptor position change
-
May 20
- CW/CCW inclinometry shows 8.8deg signature
-
May 22
- CW/CCW inclinometry OK
-
May 23
- Pointing & focus update
-
May 27
- CW/CCW inclinometry OK (Ch6 temperatures no good)
-
Jun 07
- HARP pointing tests - data seemingly unuseable
-
Jun 11
- CW/CCW inclinometry OK
-
Jun 24
- CW/CCW inclinometry OK
-
Jun 25
- K-mirror terms derived
-
Jun 29
- HARP & K-mirror pointing tests
-
Jul 02
- K-mirror terms applied to recent pointing runs
-
Jul 05
- Slicker derivation of K-mirror terms
-
Jul 13
- Tests of the new K-mirror parameter values
-
Jul 20
- All-sky HARP pointing incorporating K-mirror parameter values
-
Jul 21
- Fake pointing data : Ptest 3
-
Jul 22
- CW/CCW inclinometry OK - strain gauge data restored.
-
Jul 26
- RxA Pointing & Focus analysis : June & July 2007
-
Jul 27
- AZ/EL & RA/Dec pointing w/HARP - updated 20070801
-
Jul 29
- CW/CCW inclinometry OK
-
Aug 04
- The sign of the K-mirror corrections
-
Aug 07
- Elevation drive adjustment : impact on elevation excursions & HARP pointing
-
Aug 20
- recent HARP pointing statistics
-
Aug 23
- Assessment of Central Bearing Race Defect
-
Aug 23
- RA-Dec pointing with HARP : K-mirror terms toggled
-
Aug 30
- HARP pointing during August nights
-
Sep 03
- CW/CCW inclinometry OK
-
Sep 05
- HARP pointing during August nights - continued
-
Sep 09
- CW/CCW inclinometry OK
-
Sep 14
- Fake pointing data : Ptest 4 & 5
-
Sep 15
- CW/CCW inclinometry OK
-
Sep 19
- Tests of new K-mirror parameters
-
Sep 20
- The HARP M5 fore-optics mirror was turned around today
-
Sep 26
- Fake pointing data : Ptest 6 - 'near-constant' humidity is not enough
-
Sep 26
- A two-pronged approach to solving for the K-mirror parameters
-
Sep 27
- RxA pointing model still working well
-
Sep 28
- CW/CCW inclinometry OK
-
Oct 05
- Tests of latest K-mirror parameters
-
Oct 12
- Further analysis of pointing arcs
- no case for extra flexure term or retention of (x2,y2)
-
Oct 14
- CW inclinometry OK
-
Oct 16
- Pointing & Focus analysis : Sep & Oct 2007
-
Nov 07
- 20070823 revisted : all-sky pointing analysis
-
Nov 16
- SMU & Telescope adjustments
-
Nov 18
- CW & CCW inclinometry - not used (spike !)
-
Nov 19
- CW inclinometry OK, model not updated
-
Nov 25
- CW & CCW inclinometry OK
-
Dec 14
- SMU & Telescope adjustments; historical trends of CA IA and NPAE
-
Dec 19
- Recent pointing with HARP
-
Dec 20
- RxA pointing model OK - rms's in (az,el) = (1.6",2.0")
-
Dec 20
- Further adjustments to zero-points of SMU tables & Telescope pointing
-
Dec 23
- CW & CCW inclinometry OK
Older reports
       
POINTING home page
|
|