Image of the total surface errors (Dec 5 2001). The
measurement was made between 05:05 and 06:45 hours.
Rms of the total surface errors, from holography, is 65 microns (number was
derived from the 80 GHz moves file). The dish will be
readjusted on December 28 2001 based on the 80 GHz data (the existing software
still has to be modified in order to derive moves files from the much bigger
160 GHz files). The panel in the bottom of the dish with large errors has a
broken motor, which hopefully will be repaired soon.