Joint Astronomy Centre
Show document only
JAC Home
JCMT
UKIRT
Contact info
JAC Divisions
OMP
Outreach
Seminars
Staff-only Wiki
Weather
Web Cameras
____________________

Observing at UKIRT
Service Observing
UKIDSS Survey Operations
Target of Opportunity
Calibration & Utilities
UKIRT Archive
Public wiki
Accessing Flexed Data
Accessing UKIDSS Data
Reduction Cookbooks
Telescope
Site Quality
Instruments
Newsletter/Publications
UKIRT Faults
JAC Safety Manual
UIST Engineering


UIST logo

UIST: Engineering: Slit Wheels

UIST logo


In spectroscopic mode UIST will only be used with the 0.12"/pixel plate scale.

The instrument has a 16-slot slit wheel which contains polarimetry masks, field stops and the slits for spectroscopy. The table below lists the slit wheel's population.

25 July 2006 - Present
 
Posn Slit Description Ref
1 Small field stop (long cam) 1arcmin x 1arcmin square V
2 Long 4pixel slit with spacer* 0.48arcsec x 120arcsec K
3 Long 2pixel slit with spacer* 0.24arcsec x 120arcsec I
4 Coronographic Imaging pol mask** Two slots 20arcsec x 120arcsec (170x1024pix) with occulting wires S
5 Large field stop (short cam) 2arcmin x 2arcmin square D
6 Long 4pixel slit 0.48arcsec x 120arcsec K
7 Long 5pixel slit 0.60arcsec x 120arcsec L
8 Long 2pixel slit 0.24arcsec x 120arcsec I
9 Long 1pixel slit 0.12arcsec x 120arcsec H
10 Long 7pixel slit 0.84arcsec x 120arcsec Y
11 Pol mask imaging Two slots 20arcsec x 120arcsec (170x1024pix) F
12 Pol 2-pix spectroscopy Two slots 0.24arcsec x 20arcsec G
13 Pol 5-pix spectroscopy Two slots 0.60arcsec x 20arcsec X
14 2pixel pinhole 2pix x 2pix B
15 large hole -- N
16 IFU pick-off 5arcsec x 5arcsec square --

Note: Datum switch region posns 5-10.

*These two slits were to be used with the IJ and JH grisms (see below).
**This is essentially the same as the Pol imaging mask in posn 11, but with two wires attached across the BOTTOM (western) aperture for coronographic imaging polarimetry. Can also be used for normal coronographic imaging, though the open aperture on sky will be the same.

History

1 February 2006: Cross-dispersed spectroscopy slits in posns 2,3 and 4 removed in January 2006. These were replaced with the coronographic pol mask, and new 2-pixel and 4-pixel slits with spacers. These were to be used with the IJ and JH grisms; the equivalent slits without spacers in posns. 6 and 8 give poor focus (as does the 1-pixel slit). However, the slits with spacers didn't solve our problems, so at present these aren't being used.

25 July 2006: Tried new spacers with the Long 2/4pix slits for IJ/JH grisms. Spacers not as big this time! Also, replaced the prototype coron mask with a proper mask (with two wires, 6pix and 11 pix).

Previous slit wheel arrangement (1 Feb 2006 - 1 Aug 2006) is available here.



Contact: Chris Davis. Updated: Wed Jul 26 12:07:43 HST 2006

Return to top ^